Skip to main content
Skip table of contents

VIU2: Light module

Loxi 1 - direct / internal IN PROGRESS

Loxi 2 - diffuse / internal IN PROGRESS

Loxi 3 - diffuse / external ACTIVE

In this chapter you can read all about the Loxi3-X light module.

Overview

The Loxi3-X light module belongs to the class of direct, external lighting.

The light module consists of 8 segments with 5 LEDs each. The light module therefore has a total of 120 LEDs. These can be individually controlled in a total of 24 different areas around the diffuser plate to create light hotspots.

Different diffuser plates are inserted into the central part of the lighting to optimize the refraction of the light. A center ring shields the S-mount lens.

The diffuse lighting ensures homogeneous illumination of the area and can be used primarily for metallic surfaces, barcode and label recognition.

Ideal for reading laser markings

Laser markings and laser engravings in particular can be optimally read on metallic surfaces with the Loxi3.

Key features

  • Diffused light module

  • Lighting area: 134 mm x 101 mm

  • Individual settings for each area consisting of 5 LEDs

  • Up to 8 brightness levels for each individual LED area

Areas of application

  • Metallic surfaces

  • Organic surfaces

  • Barcodes

  • Labels

  • Field of view areas

Color coding

  • -W| White (4000K) ACTIVE

Exchange

The light module may only be replaced by a trained specialist and only when the device is switched off.

  • Shut down the system via the web interface.

  • Switch off the power supply to the evoVIU.

  • Open the four screws on the front of the evoVIU housing.

  • Open the four screws on the Loxi1-X light module.

  • Remove the circuit board and insert the adapter board into the camera.

  • First, tighten the two screws on the front docker side and make sure that the module is lying straight on the mounting surface and contacts.

  • Now tighten the two remaining screws on the module.

  • Now screw the light shield for Loxi3 in place with countersunk screws.

  • Insert the enclosed heat conductor.

  • Now insert the Loxi3 and push the contacts into the adapter board.

  • Insert the light guide disc and the diffuser plate.

  • Screw the new large Loxi3 front panel back onto the camera.

  • Switch on the camera's power supply.

  • If the LEDs flash within the next 30 seconds, you can use the new module.

New Loxi module successfully integrated

If you see a light sequence twice within the next 30 seconds, the Loxi module has been recognized by the system.

No light sequence visible

If you do not see a light sequence, check the setup again. In rare cases, a spring contact may not be making proper contact with the circuit board. If you continue to experience problems, please contact our support team.

Would you like to switch from Loxi3 to the smaller Loxi modules? Please feel free to contact us in the support area.

Variant number

XXXXX-XXX-L3-W | L3-W: White

JavaScript errors detected

Please note, these errors can depend on your browser setup.

If this problem persists, please contact our support.